The transformers are designed for installation in stationary and suspended rail welding machines of the K1100, K1000, K190, MSR6301A, K922, K900, MSR-8001, MSR-12001A, MSP-60 types.
The transformers are equipped with water cooling systems. Overheat protection sensors are installed in the coils blocks. Climatic design and location category according to GOST-15150: UHL4 (for stationary machines) and U1 (for suspended machines).
Technical specifications
Rail-welding machine |
К1000/К1100 |
МСР6301А |
МСР12001А |
К920/922 |
К900 |
К355 |
МСР80 |
Parameter |
1СТ.030.017 (К1000.02.02.000 |
1СТ.030.005 (6ЯТ.172.045 А) |
1СТ.030.001 (6ЯТ.172.058А |
1СТ.030.018 (К920.А1.01.06.000) |
1СТ.030.016 (6ЯТ.172.074) |
1СТ.030.015 (6ЯТ.172.061) |
1СТ.030.019 (6ЯТ.172.043) |
Engine power, kVA |
109 |
124 |
93 |
74,8 |
53 |
53 |
85 |
Apparent power at 50% duty cycle, kVA |
150 |
175 |
131 |
118 |
75 |
75 |
120 |
Continuous secondary current, A |
16000 |
14000 |
10700 |
10600 |
11000 |
11000 |
9800 |
Secondary current at 50% duty cycle, A |
22000 |
20000 |
15000 |
16800 |
15500 |
15500 |
13800 |
Secondary voltage, V |
6,8 |
7,92/8,84 |
8,7 |
7,04 |
7,04 |
6,3 |
8,65 |
Number of stages |
1 |
2 |
1 |
1 |
1 |
1 |
1 |
Power supply, V/Hz |
380/50 |
380/50 |
380/50 |
380/50 |
380/50 |
380/50 |
415/50 |
Cooling water consumption, l/min |
10 |
5 |
5 |
5 |
5 |
5 |
5 |
Overall dimensions, mm |
600x276x260 |
677x280x460 |
656х270х365 |
553х258х326 |
674х221хх326 |
630х326х215 |
598х268х390 |
Weight, kg |
190 |
292 |
200 |
198 |
163 |
184 |
180 |
|
|